购物车中还没有商品,赶紧选购吧!
Trek 30/20A,Non-Inverting High Voltage Amplifier, Output Voltage 0 to ±30 kV DC or Peak AC
Trek 30/20A,Non-Inverting High Voltage Amplifier, Output Voltage 0 to ±30 kV DC or Peak AC
商 城 价
累计评价0
累计销量0
手机购买
商品二维码
  
该产品价格是公开指导价,如需了解折扣价格,请点击此处。
服务
网站自营 发货并提供售后服务。
可用积分
0
数量

网站自营

加入群组

微信扫一扫

回复关键词加入群聊。

同类其他品牌

  • 商品详情
  • 规格参数
  • 相关资料
  • 用户评论(0
  • 网友讨论圈
手机购买
商品二维码
申请报价
价格:
数量:
库存  台

商品详情

商品名称:Trek 30/20A,Non-Inverting High Voltage Amplifier, Output Voltage 0 to ±30 kV DC or Peak AC
商品编号:Trek_30/20A
店铺:网站自营
封装形式:台式
输出电压:±30 kV
带宽:2.5 kHz

更多参数>>

Advanced Energys DC-stable Trek 30/20A high voltage amplifier offers a low-noise operation, expansive bandwidth, and a high slew rate. Its ideal for numerous applications including high voltage cable and component testing, and plasma studies.
  • Output Voltage: 0 to ±30 kV DC or peak AC
  • Output Current: 0 to ±20 mA DC or peak AC
  • Slew Rate: Greater than 550 V/µs
  • Large Signal Bandwidth: DC to greater than 2.5 kHz (2% distortion)
  • Gain: 3000 V/V fixed
  • Overview

    The high voltage amplifier Trek® 30/20A is DC-stable and has an all-solid-state design that enables a high slew rate, wide bandwidth, and low-noise operation. It features a non-inverting a fixed gain of 3000 V/V. It is protected against overvoltage and overcurrent conditions generated by active loads or output short circuits to the ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or feedback signals in a closed-loop system.

    Achieve accurate output responses and high slew rates demanded by reactive loads via the four-quadrant active output. It sinks or sources the current to reactive or resistive loads throughout the output voltage range.

    Benefits

    • Benefit from a closed-loop system and achieve high accuracy
    • Take advantage of complete solid-state design and maintenance-free operation
    • Rely on ultra-accurate outputs thanks to low-output noise
    • Protect against overvoltage and overcurrent conditions generated by active loads
    • Drive capacitive loads via a four-quadrant output

    Features

    • Settling time (to 1%) is less than 200 µs for a 0-30 kV step
    • Dynamically adjust to optimize AC response for various load parameters
    • Local and remote high voltage On/Off capabilities
    • NIST-traceable calibration certificate provided with each unit
    • Short-circuit protection to safeguard equipment

    资料列表

    100 好评率 %
    此商品还没有设置买家印象,陪我一起等下嘛
    暂无评价
    对比栏

    1

    您还可以继续添加

    2

    您还可以继续添加

    3

    您还可以继续添加

    4

    您还可以继续添加